Select the Correct Size Cable
The following application should help when trying to choose a suitable wire size for running
low voltage accessories (eg frige, compressor, high power lights) on your boat, truck or 4WD .
|
Important: Always ensure circuit is fused.
Fuse value never to exceed 80% of cable rating.
To prevent fire never exceed cable current rating.
Instructions: Type the applicable circuit parameters in the white boxes
and press the enter key. The most suitable size cable to perform at your
selected voltage drop will be displayed .
COPPER CABLE CHARACTERISTICS
Note: The nominal current ratings are intended as guidelines for low
power, electronics, communications and control applications only.
NOMINAL NOMINAL MAXIMUM
NUMBER CONDUCTOR CURRENT RESISTANCE NEAREST
& SIZE OF AREA RATING PER METRE EQUIVALENT
STRANDS (SQ.mm) (AMPS) (OHMS 35'C) AWG (B&S)
10 x 0.12 0.11 1.1 0.17 27
7 x 0.16 0.14 1.4 0.13 26
1 X 0.5 0.20 2.0 0.10 24
14 x 0.14 0.22 2.2 0.088 24
7 x 0.2 0.22 2.2 0.086 24
1 X 0.6 0.28 2.8 0.067 23
1 x 0.7 0.38 3.8 0.049 21
14 x 0.2 0.44 4.4 0.043 21
10 x 0.25 0.49 4.9 0.039 20
63 x 0.1 0.49 4.9 0.039 20
50 x 0.12 0.55 5.0 0.035 20
60 x 0.12 0.68 6.8 0.028 19
89 X 0.1 0.70 7.0 0.027 19
24 x 0.2 0.75 7.5 0.025 18
112 x 0.1 0.88 8.8 0.022 18
30 x 0.2 0.94 9.4 0.020 17
1 x 1.13 1.0 10.0 0.019 17
32 x 0.2 1.0 10.0 0.019 17
512 x 0.05 1.0 10.0 0.019 17
168 x 0.1 1.32 13.0 0.014 16
7 x 0.5 1.4 14.0 0.014 16
30 x 0.25 1.5 15,0 0.013 15
26 x 0.3 1.8 17.0 0.010 15
168 x 0.12 1.9 18.0 0.010 14
26 x 0.32 2.1 19.0 0.0091 14
7 x 0.67 2.5 22.0 0.0077 13
1 x 1.78 2.5 22.0 0.0076 13
252 x 0.127 3.2 29.0 0.0059 12
41 x 0.32 3.3 30.0 0.0057 12
315 x 0.12 3.6 30.0 0.0053 12
630 x 0.12 7.13 50.0 0.0027 9
1666 x 0.12 18.84 120.0 0.0010 5
|
|